浏览代码

ramips: move ESW reset to preinit on RT305x/RT5350

RT305x/RT5350 SoCs require the switch to be reset before touching the ethernet
interface, otherwise the driver will panic.
As we already init the ethernet in preinit we therefor need to reset the switch
before that.

Signed-off-by: Felix Kaechele <[email protected]>

SVN-Revision: 37027
John Crispin 12 年之前
父节点
当前提交
5063f712a6

+ 0 - 1
target/linux/ramips/base-files/etc/uci-defaults/02_network

@@ -13,7 +13,6 @@ ramips_setup_rt3x5x_vlans()
 	fi
 	local wanports=""
 	local lanports=""
-	swconfig dev rt305x set reset 1
 	for port in 5 4 3 2 1 0; do
 		if [ `swconfig dev rt305x port $port get disable` = "1" ]; then
 			continue

+ 4 - 11
target/linux/ramips/base-files/lib/preinit/07_set_preinit_iface_ramips

@@ -6,17 +6,10 @@
 . /lib/ramips.sh
 
 ramips_set_preinit_iface() {
-	local board=$(ramips_board_name)
-
-	case "$board" in
-	mpr-a2)
-		#TODO
-		# Ralink ethernet driver cannot re-open ethernet if it is opened during preinit and then closed.
-		# Looks like Ralink ethernet driver has a problem.
-		# Temporary solution is not to open ethernet during preinit.
-		return 0
-		;;
-	esac
+	RT3X5X=`cat /proc/cpuinfo | egrep "(RT3.5|RT5350)"`
+	if [ -n "${RT3X5X}" ]; then
+		swconfig dev rt305x set reset 1
+	fi
 
 	ifname=eth0
 }