Browse Source

ipq40xx: sysupgrade: drop disabled UBI to UBI logic

The commented out code is not required, as the comment
indicates.

The purpose of this code seems to be to avoid issues caused
by partially overwriting an existing UBI partition, where some
of the erase counters would be reset but not the unmodified
ones.  This problem has been solved in a more generic way by
the UBI EOF marker. This ensures that any old PEBs after the
marker are properly initialized.  It is therefore unnecessary
to erase the whole partition before flashing a new OpenWrt
factory image.

Signed-off-by: Bjørn Mork <[email protected]>
Bjørn Mork 4 years ago
parent
commit
8ac8c09f5e
1 changed files with 2 additions and 22 deletions
  1. 2 22
      target/linux/ipq40xx/base-files/lib/upgrade/linksys.sh

+ 2 - 22
target/linux/ipq40xx/base-files/lib/upgrade/linksys.sh

@@ -47,10 +47,6 @@ linksys_get_target_firmware() {
 	esac
 }
 
-linksys_get_root_magic() {
-	(get_image "$@" | dd skip=786432 bs=4 count=1 | hexdump -v -n 4 -e '1/1 "%02x"') 2>/dev/null
-}
-
 platform_do_upgrade_linksys() {
 	local magic_long="$(get_magic_long "$1")"
 
@@ -100,23 +96,7 @@ platform_do_upgrade_linksys() {
 	}
 
 	[ "$magic_long" = "27051956" ] && {
-		# This magic is for a uImage (which is a sysupgrade image)
-		# check firmwares' rootfs types
-		local oldroot="$(linksys_get_root_magic "$target_mtd")"
-		local newroot="$(linksys_get_root_magic "$1")"
-
-		if [ "$newroot" = "55424923" ] && [ "$oldroot" = "55424923" ]; then
-			# we're upgrading from a firmware with UBI to one with UBI
-			# erase everything to be safe
-			# - Is that really needed? Won't remove (or comment) the if,
-			#   because it may be needed in a future device.
-			#mtd erase $part_label
-			#get_image "$1" | mtd -n write - $part_label
-			echo "writing \"$1\" UBI image to \"$part_label\" (UBI)..."
-			get_image "$1" | mtd write - "$part_label"
-		else
-			echo "writing \"$1\" image to \"$part_label\""
-			get_image "$1" | mtd write - "$part_label"
-		fi
+		echo "writing \"$1\" image to \"$part_label\""
+		get_image "$1" | mtd write - "$part_label"
 	}
 }