- From 681b652c9dfc4037d4a55b2733e091a4e1a5de18 Mon Sep 17 00:00:00 2001
- From: AngeloGioacchino Del Regno <[email protected]>
- Date: Wed, 19 Apr 2023 08:11:46 +0200
- Subject: [PATCH 17/42] thermal/drivers/mediatek: Add temperature constraints
- to validate read
- MIME-Version: 1.0
- Content-Type: text/plain; charset=UTF-8
- Content-Transfer-Encoding: 8bit
- The AUXADC thermal v1 allows reading temperature range between -20°C to
- 150°C and any value out of this range is invalid.
- Add new definitions for MT8173_TEMP_{MIN_MAX} and a new small helper
- mtk_thermal_temp_is_valid() to check if new readings are in range: if
- not, we tell to the API that the reading is invalid by returning
- THERMAL_TEMP_INVALID.
- It was chosen to introduce the helper function because, even though this
- temperature range is realistically ok for all, it comes from a downstream
- kernel driver for version 1, but here we also support v2 and v3 which may
- may have wider constraints.
- Signed-off-by: AngeloGioacchino Del Regno <[email protected]>
- Signed-off-by: Daniel Lezcano <[email protected]>
- Link: https://lore.kernel.org/r/[email protected]
- ---
- drivers/thermal/mediatek/auxadc_thermal.c | 24 +++++++++++++++++------
- 1 file changed, 18 insertions(+), 6 deletions(-)
- --- a/drivers/thermal/mediatek/auxadc_thermal.c
- +++ b/drivers/thermal/mediatek/auxadc_thermal.c
- @@ -116,6 +116,10 @@
- /* The calibration coefficient of sensor */
- #define MT8173_CALIBRATION 165
-
- +/* Valid temperatures range */
- +#define MT8173_TEMP_MIN -20000
- +#define MT8173_TEMP_MAX 150000
- +
- /*
- * Layout of the fuses providing the calibration data
- * These macros could be used for MT8183, MT8173, MT2701, and MT2712.
- @@ -689,6 +693,11 @@ static const struct mtk_thermal_data mt7
- .version = MTK_THERMAL_V3,
- };
-
- +static bool mtk_thermal_temp_is_valid(int temp)
- +{
- + return (temp >= MT8173_TEMP_MIN) && (temp <= MT8173_TEMP_MAX);
- +}
- +
- /**
- * raw_to_mcelsius_v1 - convert a raw ADC value to mcelsius
- * @mt: The thermal controller
- @@ -815,14 +824,17 @@ static int mtk_thermal_bank_temperature(
- temp = mt->raw_to_mcelsius(
- mt, conf->bank_data[bank->id].sensors[i], raw);
-
- -
- /*
- - * The first read of a sensor often contains very high bogus
- - * temperature value. Filter these out so that the system does
- - * not immediately shut down.
- + * Depending on the filt/sen intervals and ADC polling time,
- + * we may need up to 60 milliseconds after initialization: this
- + * will result in the first reading containing an out of range
- + * temperature value.
- + * Validate the reading to both address the aforementioned issue
- + * and to eventually avoid bogus readings during runtime in the
- + * event that the AUXADC gets unstable due to high EMI, etc.
- */
- - if (temp > 200000)
- - temp = 0;
- + if (!mtk_thermal_temp_is_valid(temp))
- + temp = THERMAL_TEMP_INVALID;
-
- if (temp > max)
- max = temp;
|