123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240 |
- From aa957c759b1182aee00cc35178667f849f941b42 Mon Sep 17 00:00:00 2001
- From: Daniel Golle <[email protected]>
- Date: Wed, 30 Nov 2022 13:19:39 +0000
- Subject: [PATCH 2/2] thermal: mediatek: add support for MT7986 and MT7981
- Add support for V3 generation thermal found in MT7986 and MT7981 SoCs.
- Brings code to assign values from efuse as well as new function to
- convert raw temperature to millidegree celsius, as found in MediaTek's
- SDK sources (but cleaned up and de-duplicated)
- [1]: https://git01.mediatek.com/plugins/gitiles/openwrt/feeds/mtk-openwrt-feeds/+/baf36c7eef477aae1f8f2653b6c29e2caf48475b
- Signed-off-by: Daniel Golle <[email protected]>
- ---
- drivers/thermal/mtk_thermal.c | 137 ++++++++++++++++++++++++++++++++--
- 1 file changed, 132 insertions(+), 5 deletions(-)
- --- a/drivers/thermal/mtk_thermal.c
- +++ b/drivers/thermal/mtk_thermal.c
- @@ -150,6 +150,20 @@
- #define CALIB_BUF1_VALID_V2(x) (((x) >> 4) & 0x1)
- #define CALIB_BUF1_O_SLOPE_SIGN_V2(x) (((x) >> 3) & 0x1)
-
- +/*
- + * Layout of the fuses providing the calibration data
- + * These macros can be used for MT7981 and MT7986.
- + */
- +#define CALIB_BUF0_ADC_GE_V3(x) (((x) >> 0) & 0x3ff)
- +#define CALIB_BUF0_DEGC_CALI_V3(x) (((x) >> 20) & 0x3f)
- +#define CALIB_BUF0_O_SLOPE_V3(x) (((x) >> 26) & 0x3f)
- +#define CALIB_BUF1_VTS_TS1_V3(x) (((x) >> 0) & 0x1ff)
- +#define CALIB_BUF1_VTS_TS2_V3(x) (((x) >> 21) & 0x1ff)
- +#define CALIB_BUF1_VTS_TSABB_V3(x) (((x) >> 9) & 0x1ff)
- +#define CALIB_BUF1_VALID_V3(x) (((x) >> 18) & 0x1)
- +#define CALIB_BUF1_O_SLOPE_SIGN_V3(x) (((x) >> 19) & 0x1)
- +#define CALIB_BUF1_ID_V3(x) (((x) >> 20) & 0x1)
- +
- enum {
- VTS1,
- VTS2,
- @@ -163,6 +177,7 @@ enum {
- enum mtk_thermal_version {
- MTK_THERMAL_V1 = 1,
- MTK_THERMAL_V2,
- + MTK_THERMAL_V3,
- };
-
- /* MT2701 thermal sensors */
- @@ -245,6 +260,27 @@ enum mtk_thermal_version {
- /* The calibration coefficient of sensor */
- #define MT8183_CALIBRATION 153
-
- +/* AUXADC channel 11 is used for the temperature sensors */
- +#define MT7986_TEMP_AUXADC_CHANNEL 11
- +
- +/* The total number of temperature sensors in the MT7986 */
- +#define MT7986_NUM_SENSORS 1
- +
- +/* The number of banks in the MT7986 */
- +#define MT7986_NUM_ZONES 1
- +
- +/* The number of sensing points per bank */
- +#define MT7986_NUM_SENSORS_PER_ZONE 1
- +
- +/* MT7986 thermal sensors */
- +#define MT7986_TS1 0
- +
- +/* The number of controller in the MT7986 */
- +#define MT7986_NUM_CONTROLLER 1
- +
- +/* The calibration coefficient of sensor */
- +#define MT7986_CALIBRATION 165
- +
- struct mtk_thermal;
-
- struct thermal_bank_cfg {
- @@ -388,6 +424,14 @@ static const int mt7622_mux_values[MT762
- static const int mt7622_vts_index[MT7622_NUM_SENSORS] = { VTS1 };
- static const int mt7622_tc_offset[MT7622_NUM_CONTROLLER] = { 0x0, };
-
- +/* MT7986 thermal sensor data */
- +static const int mt7986_bank_data[MT7986_NUM_SENSORS] = { MT7986_TS1, };
- +static const int mt7986_msr[MT7986_NUM_SENSORS_PER_ZONE] = { TEMP_MSR0, };
- +static const int mt7986_adcpnp[MT7986_NUM_SENSORS_PER_ZONE] = { TEMP_ADCPNP0, };
- +static const int mt7986_mux_values[MT7986_NUM_SENSORS] = { 0, };
- +static const int mt7986_vts_index[MT7986_NUM_SENSORS] = { VTS1 };
- +static const int mt7986_tc_offset[MT7986_NUM_CONTROLLER] = { 0x0, };
- +
- /*
- * The MT8173 thermal controller has four banks. Each bank can read up to
- * four temperature sensors simultaneously. The MT8173 has a total of 5
- @@ -551,6 +595,30 @@ static const struct mtk_thermal_data mt8
- .version = MTK_THERMAL_V1,
- };
-
- +/*
- + * MT7986 uses AUXADC Channel 11 for raw data access.
- + */
- +static const struct mtk_thermal_data mt7986_thermal_data = {
- + .auxadc_channel = MT7986_TEMP_AUXADC_CHANNEL,
- + .num_banks = MT7986_NUM_ZONES,
- + .num_sensors = MT7986_NUM_SENSORS,
- + .vts_index = mt7986_vts_index,
- + .cali_val = MT7986_CALIBRATION,
- + .num_controller = MT7986_NUM_CONTROLLER,
- + .controller_offset = mt7986_tc_offset,
- + .need_switch_bank = true,
- + .bank_data = {
- + {
- + .num_sensors = 1,
- + .sensors = mt7986_bank_data,
- + },
- + },
- + .msr = mt7986_msr,
- + .adcpnp = mt7986_adcpnp,
- + .sensor_mux_values = mt7986_mux_values,
- + .version = MTK_THERMAL_V3,
- +};
- +
- /**
- * raw_to_mcelsius - convert a raw ADC value to mcelsius
- * @mt: The thermal controller
- @@ -605,6 +673,22 @@ static int raw_to_mcelsius_v2(struct mtk
- return (format_2 - tmp) * 100;
- }
-
- +static int raw_to_mcelsius_v3(struct mtk_thermal *mt, int sensno, s32 raw)
- +{
- + s32 tmp;
- +
- + if (raw == 0)
- + return 0;
- +
- + raw &= 0xfff;
- + tmp = 100000 * 15 / 16 * 10000;
- + tmp /= 4096 - 512 + mt->adc_ge;
- + tmp /= 1490;
- + tmp *= raw - mt->vts[sensno] - 2900;
- +
- + return mt->degc_cali * 500 - tmp;
- +}
- +
- /**
- * mtk_thermal_get_bank - get bank
- * @bank: The bank
- @@ -885,6 +969,25 @@ static int mtk_thermal_extract_efuse_v2(
- return 0;
- }
-
- +static int mtk_thermal_extract_efuse_v3(struct mtk_thermal *mt, u32 *buf)
- +{
- + if (!CALIB_BUF1_VALID_V3(buf[1]))
- + return -EINVAL;
- +
- + mt->adc_ge = CALIB_BUF0_ADC_GE_V3(buf[0]);
- + mt->degc_cali = CALIB_BUF0_DEGC_CALI_V3(buf[0]);
- + mt->o_slope = CALIB_BUF0_O_SLOPE_V3(buf[0]);
- + mt->vts[VTS1] = CALIB_BUF1_VTS_TS1_V3(buf[1]);
- + mt->vts[VTS2] = CALIB_BUF1_VTS_TS2_V3(buf[1]);
- + mt->vts[VTSABB] = CALIB_BUF1_VTS_TSABB_V3(buf[1]);
- + mt->o_slope_sign = CALIB_BUF1_O_SLOPE_SIGN_V3(buf[1]);
- +
- + if (CALIB_BUF1_ID_V3(buf[1]) == 0)
- + mt->o_slope = 0;
- +
- + return 0;
- +}
- +
- static int mtk_thermal_get_calibration_data(struct device *dev,
- struct mtk_thermal *mt)
- {
- @@ -895,6 +998,7 @@ static int mtk_thermal_get_calibration_d
-
- /* Start with default values */
- mt->adc_ge = 512;
- + mt->adc_oe = 512;
- for (i = 0; i < mt->conf->num_sensors; i++)
- mt->vts[i] = 260;
- mt->degc_cali = 40;
- @@ -920,10 +1024,20 @@ static int mtk_thermal_get_calibration_d
- goto out;
- }
-
- - if (mt->conf->version == MTK_THERMAL_V1)
- + switch (mt->conf->version) {
- + case MTK_THERMAL_V1:
- ret = mtk_thermal_extract_efuse_v1(mt, buf);
- - else
- + break;
- + case MTK_THERMAL_V2:
- ret = mtk_thermal_extract_efuse_v2(mt, buf);
- + break;
- + case MTK_THERMAL_V3:
- + ret = mtk_thermal_extract_efuse_v3(mt, buf);
- + break;
- + default:
- + ret = -EINVAL;
- + break;
- + }
-
- if (ret) {
- dev_info(dev, "Device not calibrated, using default calibration values\n");
- @@ -954,6 +1068,10 @@ static const struct of_device_id mtk_the
- .data = (void *)&mt7622_thermal_data,
- },
- {
- + .compatible = "mediatek,mt7986-thermal",
- + .data = (void *)&mt7986_thermal_data,
- + },
- + {
- .compatible = "mediatek,mt8183-thermal",
- .data = (void *)&mt8183_thermal_data,
- }, {
- @@ -1068,15 +1186,24 @@ static int mtk_thermal_probe(struct plat
- goto err_disable_clk_auxadc;
- }
-
- - if (mt->conf->version == MTK_THERMAL_V2) {
- + if (mt->conf->version != MTK_THERMAL_V1) {
- mtk_thermal_turn_on_buffer(apmixed_base);
- mtk_thermal_release_periodic_ts(mt, auxadc_base);
- }
-
- - if (mt->conf->version == MTK_THERMAL_V1)
- + switch (mt->conf->version) {
- + case MTK_THERMAL_V1:
- mt->raw_to_mcelsius = raw_to_mcelsius_v1;
- - else
- + break;
- + case MTK_THERMAL_V2:
- mt->raw_to_mcelsius = raw_to_mcelsius_v2;
- + break;
- + case MTK_THERMAL_V3:
- + mt->raw_to_mcelsius = raw_to_mcelsius_v3;
- + break;
- + default:
- + break;
- + }
-
- for (ctrl_id = 0; ctrl_id < mt->conf->num_controller ; ctrl_id++)
- for (i = 0; i < mt->conf->num_banks; i++)
|